• The light source can only be replaced by the manufacturer, a service agent or similarly qualified per-
son to avoid hazard.
Note Condensation moisture on glass doors
When the ambient humidity is above 25 % in 25 °C ambient temperature, moisture will condense on the
glass door.
Clean the minibar regularly and as soon as it becomes dirty with a damp cloth.
Wipe the minibar dry with a cloth after cleaning.
Check the condensate drain regularly.
Clean the condensate drain when necessary. If it is blocked, the condensate collects on the bottom of the
minibar.
For absorber versions: Use a brush or so cloth annually to remove dust from the absorber unit.
9 Troubleshooting
Problem
The minibar is not cooling.
Minibar is not cooling. Indicator LED is
continuously flashing.
Poor cooling performance
14
Possible cause
Power plug is not plugged in.
No voltage at the socket.
Electronics or sensors defective
For versions with absorber cool-
ing: Heating cartridge defective
Auto-defrost function is active.
Minibar was recently switched on.
Cooling unit is defective.
Minibar is in silent mode.
Cooling unit is blocked.
Cooling unit is not water-tight.
Heating element is defective.
Error during self-test
Cooling unit is not sufficiently ventilat-
ed.
Minibar is exposed to direct sunlight.
Dometic HiPro Apollo, Evolution
Suggested remedy
Insert power plug into socket.
Check circuit breaker.
Contact an authorized service
agent.
Service agent only: Install new
electronics or sensor.
Contact an authorized service
agent.
Service agent only: Install new
heating cartridge.
No action required (see chapter
frosting
on page 13).
Check cooling again after 5 h ... 6 h.
Contact an authorized service
agent.
Service agent only: Replace
the minibar.
No action required
(Setting the silent
mode (only for C40)
on page 12).
Contact an authorized service agent.
Provide sufficient ventilation (see Instal-
lation Manual).
Remove the minibar out of direct sun-
light.