ASC 5300 G
Service tasks
11. Replace the O-rings (E). Moisten new O-rings with refrigerant oil
before installing.
E
12. Insert the new dryer and tighten the screw to max. 15 Nm.
13. Reconnect the power plug.
14. Switch on the unit.
✓ The inverter performs a self-test.
15. Fasten the cover again.
EN
111