Screw terminals 1 and 3:
Counting input and reset input
Optocoupler input 10...260 V AC/V DC
galvanic isolation, active for High signal
Min. pulse duration:
16 ms
Max frequency:
approximately 30 Hz
Low level:
0...2 V AC/V DC
High level:
10...260 V AC/V DC
Input resistance:
approximately 160 kOhm
AC mains frequency: 50/60Hz
Screw terminal 2:
Common AC/DC, common connection for the optocoup-
ler inputs (screw terminals 1 and 3).
Screw terminal 4:
Electrical locking of the reset key
Contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
0...0.7 V DC
High level:
3...5 V DC
Input resistance:
approximately 2.2 MOhm
Input not active:
Reset key locked
Input in contact with GND:
Reset key unlocked
Screw terminal 5:
Function: see table 3, active for negative edge
Contact input/Open Collector NPN
(switching at 0 V DC)
Low level:
0...0.7 V DC
High level:
3...5 V DC
Min. pulse duration:
50 ms
Input resistance:
ca. 2.2 MOhm
Input High:
- - -
Input Low:
Reset of the counter
Dynamic resetting behaviour
Page 6 | ENG
Screw terminal 6:
Common GND connection for screw terminal 4 (reset
key locking input) and screw terminal 5 (reset input).
Screw terminal 7:
(–) external power supply for the backlight option
Screw terminal 8:
(+) external power supply for the backlight option
(24 V ±20%, 50 mA), Fuse T0.08 A, delayed action
All low voltages, SELV, reinforced/double
!
insulation.
Signal inputs must be protected with an exter-
DANGER
nal delayed T0.01 A fuse when the source
does not provide protective impedance (fuse/
current limitation).
Scope of delivery:
Digital dispay
Clamp
Front frame for screw mounting,
Panel cut-out 50 x 25 mm
Front frame for clamp mounting,
Panel cut-out 50 x 25 mm
Seal
Operating instructions
Note:
t
This product includes a lithium battery. Do
not open it by force, do not throw it in the
fire. Avoid temperatures below –20 °C and
above +70 °C!