Descargar Imprimir esta página

ims PRO TIG PRO 161 DC Manual página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
FUNCTION, MENU AND PICTOGRAM DESCRIPTIONS
FUNCTION
HF ignition
Lift ignition
Pre-gas
Up slope current
Welding current
Cold current/Background
current)
PULSE Frequency
Down slope current
Post-gas
HotStart
ArcForce
TIG PULSE
TIG SPOT
MMA PULSE
2T
4T
4T LOG
Ampere (unit)
Volt (unit)
Second or Hertz (units)
Percentage (unit)
Display switch A or V
Program menu access
Thermal protection
Sleep mode
TIG PRO 161 DC
TIG
PICTOGRAM
MMA
DC
Comments
TIG process with HF ignition
TIG process with LIFT ignition
Time to purge the torch and to protect the area with gas before ignition
Up slope current
Welding current
Second welding current or «cold» current in standard 4TLOG or in PULSE
mode
PULSATION frequency of the PULSE mode (Hz)
Down slope current to minimum current, I Stop (S) to prevent weld defects
and craters.
Duration for which gas is released after the arc has stopped. It protects the
weld pool and the electrode against oxidization when the metal is cooling (S).
Adjustable overcurrent at the beginning of the welding (%)
Overcurrent delivered to avoid sticking when the electrode enters the welding
pool
Pulse mode
Spot mode
MMA process in PULSE mode
2 time torch mode
4 time torch mode
4 time LOG torch mode
Amperes unit for welding current settings
Volt unit for displaying welding voltage
Seconds or Hertz unit for time or frequency settings
Percentages unit for proportionate settings
Switches the display of voltage or current during and after welding
Access to configuration menu (SAVE, JOB, ...)
Standard symbol to indicate the thermal protection state
Sleep mode
EN
19

Publicidad

loading