Installation
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Screw T distributor to the connection socket, screw nozzle tube to the T distributor (A1). Screw nozzle mounting and
the desired water feature nozzle to the nozzle tube (A2). It is possible to connect a hose to the lateral outlet at the T
distributor by means of the reduction element and the stepped hose connection (A3). Place the unit in the pond hori-
zontally on firm, sludge-free ground and ensure that it is completely covered with water (at a maximum of 2 m below
the water level).
Align the nozzle tube. The water feature height and the water flow can be adjusted with a regulator at the lateral outlet
at the T distributor (B). The power supply must be disconnected to switch off the unit.
Set-up the unit
Note!
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear
and will require earlier replacement.
Remedy:
• Thoroughly clean the pond or pool before installing the pump.
• Install the pump approx. 200 mm above the floor of the pond to avoid excessively soiled water from being
drawn into the pump.
• Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely covered
with water.
Commissioning/start-up
Sensitive electrical components.
Possible consequences: The device will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
Attention! The pump must never run dry.
Possible consequence: The pump will be destroyed.
Protective measure: Check the water level at regular intervals. Always place the unit below water level.
Attention! Risk of injury due to unexpected start-up.
The temperature monitor switches the unit off automatically in the event of overload. The unit is switched on
again automatically as soon as it has cooled down.
Possible consequences: Risk of injury due to fast rotating components.
Protective measures: Always isolate the unit (switch off and disconnect from the power supply) before start-
ing any work on the unit.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.