Descargar Imprimir esta página

Bertazzoni KT90MAS1NEC Manual De Uso página 11

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
1. SAFETY INFORMATION
EN
For your safety and correct
operation of the appliance,
read this manual carefully before
installation and use. Always keep
these instructions with the ap-
pliance even if you move or sell
it. Users must fully know the
operation and safety features of
the appliance.
The wire connection has to
be done by specialized
technician.
• The manufacturer will not be
held liable for any damages
resulting from incorrect or im-
proper installation.
• The minimum safety distance
between the cooker top and
the extractor hood is 650 mm
(some models can be installed
at a lower height, please refer
to the paragraphs on working
dimensions and installation).
• If the instructions for installa-
tion for the gas hob specify a
greater distance, this must be
respected.
• Check that the mains voltage
corresponds to that indicated
on the rating plate fixed to the
inside of the hood.
• Means for disconnection must
be incorporated in the fixed
wiring in accordance with the
wiring rules.
• For Class I appliances, check
that the domestic power supply
guarantees adequate earthing.
• Connect the extractor to the
exhaust flue through a pipe of
minimum diameter 120 mm.
The route of the flue must be
as short as possible.
• Regulations concerning the dis-
charge of air have to be fulfilled.
• Do not connect the extractor
hood to exhaust ducts carrying
combustion fumes (boilers, fire-
places, etc.).
• If the extractor is used in con-
junction with non-electrical
appliances (e.g. gas burning
appliances), a sufficient degree
of aeration must be guaranteed
in the room in order to prevent
the backflow of exhaust gas.
When the cooker hood is used
in conjunction with appliances
supplied with energy other than
electric, the negative pressure in
the room must not exceed 0,04
mbar to prevent fumes being
drawn back into the room by
the cooker hood.
• The air must not be discharged
into a flue that is used for ex-
hausting fumes from appliances
burning gas or other fuels.
• If the supply cord is damaged, it
must be replaced from the man-
ufacturer or its service agent.
• Connect the plug to a socket
complying with current regula-
tions, located in an accessible
place.
• With regards to the technical
and safety measures to be
adopted for fume discharging
11

Publicidad

loading