can start. At the end of the stroke, the right-hand sensor goes low,
measurement ends and the time difference between the two
flanks is displayed.
Limitations
The longest possible measuring time is 60 seconds.
7.5
Fig. 9:
1. Apply the sensor to the cylinder (1).
2. Connect the M8 cable between the box and the "Start"
connector of the meter (2).
3. Connect the two M12 connectors to the box and connect the
cables to the pilot connections of the valve (3).
4. Connect the mains adapter (24 V) (4).
5. Switch on the instrument by pressing "On".