G
B
POINT B - SETTINGS
DIP 1
MAINTENANCE CHECK (See Page 37)
DIP 2
PROGRAMMING (See Point C)
DIP 2-1 PROGRAMMING OF PEDESTRIAN OPENING (See Point D)
DIP 1-2 SAVE/DELETE RADIO CODES FOR COMPLETE OPENING (DIP 1 ON followed
by DIP 2 ON) (POINT E)
DIP 1-3 SAVE/DELETE RADIO CODES FOR PEDESTRIAN OPENING (DIP 1 ON
followed by DIP 3 ON) (POINT F)
DIP 1-2-3 SAVE/DELETE RADIO CODES FOR RELAY R-AUX COMMAND (point G)
DIP SWITCHES CONTROL
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
DIP 7
Photocells AUTO-TEST activation (ON-activated).
DIP 8
Encoder management (ON - activated) for PLUS models - with encoder
DIP 9
Slowdown (ON - activated)
DIP 10
Electronic brake (ON-activated)
DIP 11
Gradual start (ON-activated)
DIP 12
Activate the radio system SUN (ON) - SUN-PRO (OFF)
DIP 13
Contactors management (ON - activated) - NOTE: Even if enabled, DIPs 8-9-10-11
are excluded from their operation
DIP 14
DIP 15
OFF
OFF
ON
OFF
OFF
ON
TORQUE TRIMMER - Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE Trimmer which varies the output
voltage to the head/s of the motor/s (turn clockwise to increase torque).
This torque control is activated after 2 seconds form any manoeuvre begging, whereas the
motor is turned on at full power to guarantee the starting at the manoeuvre begging.
PAY ATTENTION: IF THE TORQUE TRIMMER SETTING IS CHANGED, IT IS PREFERABLE
TO REPEAT THE TIME PROGRAMMING.
LOW SPEED TRIMMER - Electronic regulator for low speed on approach
Adjustment of low speed is carried out using the LOW SPEED Trimmer which varies the
output voltage to the head/s of the motor/s (turn clockwise to increase speed). Adjustment
is carried out to establish the correct speed at the completion of opening and closing,
depending on the structure of the gate, or if there is any light friction that could compromise
the correct working of the system.
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN
openings
default NOT ACTIVATED and LED DL11 OFF (trimmer fully rotated counterclockwise)
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic
closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11
ON (trimmer rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a
maximum of 2 minutes.
The pause time (for gate open with PED. control) can be adjusted from a minimum of 2
seconds to a maximum of 30 seconds.
Ex: With TCA trimmer setted halfway, you will have 1 minute pause after the total opening
and 15 seconds of pause after the pedestrian opening prior to have the auto-close of
the gate.
R-AUX - AUXILIARY RELAY CONTACT (NO)
By default this relay is set as courtesy light (max 700 W - 3 A - 230 Vac) to operate 3 minutes
at each command, with time renewed at each command.
You can activate the R-AUX contact by TRANSMITTER by performing the memorization
procedure described in point G.
ELECTRONIC BRAKE
If DIP 10 is turned ON, the electronic brake will activate upon total opening or closing.
GRADUAL START
If DIP11 is turned ON, a gradual movement will be enabled for 1second upon each starting.
In case of an obstacle is detected by any safety inputs (photocell, safety strip or encoder), the
gradual start is bypassed for the time being to guarantee a more prompt and safe reaction.
LED WARNINGS
DL1
PROG programming activated
DIP 16
MOTOR TYPE
OFF
K800
OFF
K1400
OFF
K2200
(red)
DL2
Gate opening
DL3
Gate closing
DL4
Opening limit switch LSO
DL5
Closing limit switch LSC
DL6
STOP command (NC)
DL7
PHOTO 1 contact (NC)
DL8
PHOTO 2 contact (NC)
DL9
EDGE 1 contact (NC)
DL10 EDGE 2 contact (NC)
DL11 TCA - automatic closure time enabled
DL12 Remotes programming enabled
DL13 L1 managed by APP
DL14 Encoder enabled
DL15 PROG and RADIO (on MOLEX connector) commands (green)
B.I.O
Clock command (NO)
PED.
Pedestrian command (NO)
START Single impulse command (NO)
CLOSE CLOSE command (NO)
OPEN OPEN command (NO)
PROBE
It's a cable ended with a sensor to detect the motor temperature and, if necessary, to active
automatically the motor warming (code ACG4665).
POINT C - TIMES PROGRAMMING
N.B .: During the programming the safety functions Coast, Photocells, Stop button
and Impact detection are active and their performance level is pl "b" according
to EN13849-1. their intervention stops the programming (the led DL1 from
flashing remains lit steadily).
N.B .: If the STOP, PHOT 1, PHOT 2, EDGE 1 and EDGE 2 inputs are not connected,
make jumpers between COM A +/STOP/PHOT 1/PHOT 2/EDGE 1/EDGE 2 before
proceeding with programming. N.B .: In this case the safety Edge, Photocells
and Stop button will be ignored.
N.B .: The start slow-down point is automatically determined in the time programming phase
and 50 ÷ 60 cm is activated before reaching the opening or closing limit switch.
N.B.: TO REPEAT THE PROGRAMMING REPOSITION THE GATE TO 20 CM FROM THE
CLOSING LIMIT SWITCH AND FOLLOW THE PROCEDURES BELOW.
- PROGRAMMING WITHOUT ENCODER (DEDICATED TO K800 - K1400 - K2200
ENGINES) N.B .: THE DIP 8 MUST BE ON OFF !!
- PROGRAMMING WITH ENCODER (DEDICATED TO K800 - K1400 - K2200 ENGINES
with SET PLUS ACG5460) N.B .: THE DIP 8 MUST BE ON ON !!
1 - N.B .: POSITION THE GATE TO ABOUT 20 CM FROM THE CLOSING LIMIT SWITCH.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG or START or OPEN button or the button of the remote control dedicated
to the total opening (if previously programmed). The gate will start a series of movements.
DO NOT PASS IN FRONT OF THE PHOTOCELLS WHILE THE GATE IS MOVING. The
programming ends when the gate is closed and the DL1 LED is off.
4 - AT THE END OF PROGRAMMING, RESET THE DIP 2 ON OFF.
D - PROGRAMMING OF PEDESTRIAN OPENING TIMES
With closed gate and closing limit switch engaged (mandatory).
1 - First set DIP 2 to ON (LED DL1 flashes quickly) and after DIP1 to ON (LED DL1 flashes
slowly).
2 - Press the PED pedestrian button. or the remote control button dedicated to the pedestrian
opening (if previously programmed) => The gate opens.
3 - Press the pedestrian button PED. to stop the run (thus defining the opening of the gate).
4 - Press the pedestrian button to start closing.
5 - When the closing limit switch is reached, reset DIP1 and 2 to OFF.
During programming, the safety devices are active and their intervention stops the
programming (the LED from blinking remains lit steadily and the buzzer sounds for 10
seconds).
To repeat the programming position the DIP1 and 2 on OFF, close the gate and repeat the
procedure described above.
F - RADIO CODES PROGRAMMING PROCEDURE FOR TOTAL OPENING
(1000 CODES MAX) - with radio module ACG8069
ATTENTION: before storing the radio codes, use DIP 12 to select which transmitters to use:
DIP 12 OFF: SUN-PRO variable code transmitters can be memorized:
SUN-PRO 2CH 2-channel - red keys and white led cod. ACG6210
SUN-PRO 4CH 4-channel - red keys and white led cod. ACG6214
34
(green)
(red)
(green)
(red)
(red)
(red)
(red)
(red)
(red)
(red)
(two colors)
(blue)
(red)
(green)
(green)
(green)
(green)
(green)