PROBLEM
Not pumping water
Flow rate is too low
OPERATION
TROUBLESHOOTING
POSSIBLE CAUSE
Impeller blockage.
Outlet line positioned
too high.
Outlet line is too long.
Inlet/Outlet line is
clogged or damaged.
Inlet connection not
air tight.
Impeller cover is not
secured tightly.
Impeller worn out.
7 – English
POSSIBLE SOLUTION
See Replacing the Impeller and O-Ring in the Maintenance
section of this manual.
Lower the outlet hose height to below the height listed in the
Product Specifications.
Use a shorter length of outlet line if possible.
Replace Inlet/Outlet line. Check lines for blockages, kinks or
bends. Clear blockages.
Tighten inlet connection. Add pipe thread tape or a gasket if
necessary.
Hand tighten four (4) cover screws.
See Replacing the Impeller and O-Ring in the Maintenance
section of this manual.