3x4 mm² 230V~
5x2,5 mm² 2L+2N 230V~
For the induction hob, the cable must
be H05VV-F 3X4 mm² 60227 IEC 53
••. You will find the connection diagram
shown on the bottom of your appliance.
ERROR CODES
If there is an error, error code will be
showed at heater displays.
E1 : The cooling Fan is disabled, call
an authorized service agent.
E3 : The power supply voltage is over
the rated values, turn the hob off by
5x2,5 mm² 400V 3N~
touching
for all zones, turn the hob on by pres-
sing
to use. If same error appears, call an
authorized service agent.
E4 : Supply frequency is different from
the rated values, turn the hob off by
touching
ars for all zones, turn the hob on by
pressing
same error appears, plug off/on turn
the hob on by pressing
to use it. If the same error appears, call
an authorized service agent.
E5 : The hob inside temperature is too
high, turn the hob off by pressing
to let the heaters cool down.
E6 : Communication error between
touch control and heater, call an aut-
horized
service agent.
E7 : The coil temperature sensor is
disabled, call an authorized service
agent.
E8: The cooler temperature sensor is
disabled, call an authorized service
agent.
E9 : Calibration error, call an authori-
zed service agent.
EN 17
,wait until "H" disappears
and continue
, wait until "H" disappe-
and continue to use. If
continue