PARAMETER
Code
Name
S.453 Spd PI Low lim
Speed PI regulator output lower limit
S.901 Save parameters
Save parameters
Source of the Enable command of Lift
I.000 Enable src
Control Word
AGL50-EV
DESCRIPTION
off"
do
[0] False
[1] True
[2] DI 1
[3] DI 2
[4] DI 3
[5] DI 4
[6] DI 5
[7] DI 6
[8] DI 7
[9] DI 8
[10] DI Exp 1
[11] DI Exp 2
[12] DI Exp 3
[13] DI Exp 4
[14] AND 1
[15] AND 2
[16] AND 3
[17] OR 1
[18] OR 2
[19] OR 3
[20] NOT 1
[21] NOT 2
[22] NOT 3
[23] NOT 4
PICK LIST
Selection
Description
INTERFACE
The command is never
active
The command is always
active
The command comes
from DigInp1
The command comes
from DigInp2
The command comes
from DigInp3
The command comes
from DigInp4
The command comes
from DigInp5
The command comes
from DigInp6
The command comes
from DigInp7
The command comes
from DigInp8
The command comes
from ExpDI 1
The command comes
from ExpDI 2
The command comes
from ExpDI 3
The command comes
from ExpDI 4
The command comes
from the output of the
block AND1
The command comes
from the output of the
block AND2
The command comes
from the output of the
block AND3
The command comes
from the output of the
block OR1
The command comes
from the output of the
block OR2
The command comes
from the output of the
block OR3
The command comes
from the output of the
block NOT1
The command comes
from the output of the
block NOT2
The command comes
from the output of the
block NOT3
The command comes
from the output of the
block NOT4
Def.
Min
Max
Unit
% of
-10
-100
0
F.020
off"
off"
("do")
2
0
27
Variat.
IPA
510
0.1
(P.177)
800
(C.000)
100
47