Franklin Electric WS Serie Instrucciones De Uso página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. AUTOMATIC MODELS (WITH FLOAT SWITCH)
SINGLE PHASE 115 AND 230 VAC MODELS:
a) Connect the 3-prong grounded piggyback plug on
the fl oat switch cord into a 115 or 230 vac (depend-
ing on your model) ground fault interrupter (GFI)
receptacle.
DO NOT REMOVE GROUND PRONG FROM
PLUG.
DO
NOT
CORD.
b) Connect the 3-prong grounded plug from the
pump power cord into the piggy back receptacle
on the back of switch plug. DO NOT REMOVE
GROUND PRONG
USE AN EXTENSION CORD.
c) Manually fi ll the tank/basin with water to check the
switch operation. DO NOT RUN DRY.
d) Ensure that the fl oat switch hangs free and the
START /STOP levels are satisfactory. The fl oat
switch MUST NOT COME IN CONTACT WITH
SIDES OR BOTTOM OF TANK / BASIN.
e) Cycle your system a few times to ensure that
its operation is satisfactory. Replace tank/basin
cover and double check to ensure that all system
components/requirements are in place.
11. SAFETY TIPS
RISK OF ELECTRICAL SHOCK
- BODILY INJURY
a) Always wear rubber boots when you must unplug
the pump from the power supply.
b) Never make adjustments or do maintenance
checks with power connected. Always disconnect
your pump from the electrical power supply before
beginning ANY service.
c) DO NOT SMOKE OR USE SPARKABLE ELEC-
TRICAL DEVICES OR FLAME IN A SEPTIC
(GASEOUS) SUMP.
d) A SEPTIC SUMP CONDITION MAY EXIST. If
entry into sump is necessary, fi rst provide proper
safety precautions per OSHA requirements and
secondly, DO NOT ENTER SUMP UNTIL THESE
PRECAUTIONS ARE STRICTLY ADHERED
TO.
e) NEVER REMOVE GROUND PRONG FROM
ANY POWER OR SWITCH PLUG. This is the
ground and is there for your safety.
START UP AND OPERATIONAL CHECK
USE
AN
EXTENSION
FROM PLUG.
DO NOT
SAFETY TIPS AND MAINTENANCE
WARNING:
9. MANUAL MODELS:
SINGLE PHASE 115 AND 230 VAC MODELS
a) Manually fi ll the tank/basin with water to check the
pump's operation. DO NOT RUN DRY.
b) Connect the 3-prong grounded plug on the pump
power cord into 115 or 230 VAC (depending on your
model) ground fault interrupter (GFI) receptacle
or approved motor control. DO NOT REMOVE
GROUND PRONG FROM PLUG.
USE AN EXTENSION CORD.
c) Cycle your system a few times to ensure that
its operation is satisfactory. Replace tank/basin
cover and double check to ensure that all system
components/requirements are in place.
10. MANUAL MODELS:
THREE PHASE 230, 460 & 575 VAC MODELS
a) Manually fi ll the tank/basin with water to check the
pump's operation. DO NOT RUN DRY.
b) After the pump power cord has been wired to an
approved, properly sized and grounded three phase
motor control, cycle your system a few times to
ensure that its operation is satisfactory. Replace
tank/basin cover and double check to ensure that all
system components/requirements are in place.
12. MAINTENANCE:
ED SO THAT NO REGULAR MAINTENANCE IS
REQUIRED SINCE THE PUMP IS COMPLETELY
SELF LUBRICATING. THE FOLLOWING ROUTINE
CHECKING PROCEDURE IS RECOMMENDED TO
BE CONDUCTED EACH YEAR - AND ESPECIALLY
IMPORTANT FOR OCCASIONAL USE APPLICA-
TIONS.
a) Check power cords, switch cords and electrical
service outlets for damage and corrosion.
b) Ensure there is no build up of sludge, sediment or
blockage in the tank/basin to clog the pump.
c) Manually raise and lower the fl oat switch to ensure
correct pump operation (important for occasional
use applications).
d) Manually fi ll the tank/basin to check for correct
switch adjustment and system operation.
6
YOUR PUMP IS CONSTRUCT-
DO NOT

Publicidad

Tabla de contenido
loading

Tabla de contenido