OPERATING INSTRUCTIONS
2
Safety information
2.1
Correct use
3
Product description
3.1
Operating elements and status indicators
en
Table 1: Display and operating elements
WL34-Bx4x
1
H
5
t 2
D
6
t 1
NPN
t 1
t 2
7
PNP
t 0
t 1 + t 2
Yellow LED indicator
1
Potentiometer: sensi‐
2
tivity adjustment
Switch: light (L) / dark
3
(D)
Switch: NPN / PNP
4
Potentiometer: adjust‐
5
ment of time delay t
Potentiometer: adjust‐
6
ment of time delay t
Potentiometer: adjust‐
7
ment of time stage
4
Mounting
22
O P E R A T I N G I N S T R U C T I O N S | WL34
Connection, mounting and configuration of the product must only be car‐
ried out by qualified personnel.
This product does not constitute a safety component as defined in the
NO
Machinery Directive.
2006/42/EC
SAFETY
Do not install the product in places exposed to direct UV radiation (sun‐
light) or other weather conditions.
The product must be adequately protected against moisture and contami‐
nation.
WL34-Xx3x
1
2
2
H
3
3
D
NPN
4
PNP
4
Yellow LED indicator
1
Potentiometer: sensi‐
2
tivity adjustment
Switch: light (L) / dark
3
(D)
Switch: NPN / PNP
4
2
1
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
WL34-Rx4x
1
2
4
H
3
t
2
D
5
t 1
6
t 1
t 2
t
0
t
+ t
1
2
Yellow LED indicator
1
Potentiometer: sensi‐
2
tivity adjustment
Switch: light (L) / dark
3
(D)
Potentiometer: adjust‐
4
ment of time delay t
2
Potentiometer: adjust‐
5
ment of time delay t
1
Potentiometer: adjust‐
6
ment of time stage
WL34-Rx3x
1
2
H
3
D
Yellow LED indicator
1
Potentiometer: sensi‐
2
tivity adjustment
Switch: light (L) / dark
3
(D)
8009201.1DM8/2022-09-05 | SICK
Subject to change without notice