For the DDA-400 and DDA-750 models:
This process is done automatically, but you will always have the option to perform a
defrost cycle manually by following the steps explained above.
5.4.3 Maintenance.
Through these guidelines we want to offer help both to you and to the technical
assistance service, so that throughout the useful life of the cabinet you always continue
to provide an unbeatable service.
We will discuss the cleaning that you can perform, as well as a brief check of the
machine before contacting the technical service. We hope it is useful to you.
5.4.3.1 Cleaning to be done by the user.
Before carrying out any cleaning operation, press the thermostat button
sure that the equipment is OFF and once done, remove the plug from the socket. It is
considered disconnected when the plug has been removed.
WARNING
Make sure that the cleaning water does not get on any of the electrical components or
the ventilation grille.
Be careful not to damage or remove the nameplate inside the machine, as it is
important for our customer service.
5.4.3.2 Air renewal through the active carbon filter.
The filter should be changed once a year to ensure the full efficiency of the carbon
filter.
Filter change: Remove the screws at the bottom of the appliance, remove the cover
5.4.3.3 UVC light change.
If this option is included, for the replacement you must unscrew and remove the sheet
metal part of the backrest, which serves as an air channel. Once the sheet is removed,
ES
: Do not use steam robots for cleaning! Risk of damage and injury.
and the filter inside, and replace it with another filter.
Later you must put the filter cover with its respective screws.
and make
33