3.3
Meaning of the LEDs
LEDs on the thermal imaging camera
LED
LED 1 flashes green
(2 Hz)
LED 1 lights green
LED 2 lights green
LED 2 lights yellow
LED 2 lights red
LED 3 slowly flashes
blue (2 Hz)
LED 3 lights blue
LEDs 1 and 2 rapidly
flash red (4 Hz)
LEDs 1 and 2 light red
LEDs on the charging cradle
There are 4 LEDs on the charging cradle which indicate the status of the
charging process.
LED
LED 1 lights green
All 4 LEDs light green
LEDs 1, 2 and 3 light
green; LED 4 flashes
green (1 Hz)
LEDs 1 and 2 light green;
LED 3 flashes green
(1 Hz)
LED 1 lights green;
LED 2 flashes green
(1 Hz)
All 4 LEDs slowly flash-
ing yellow (2 Hz)
Dräger UCF FireCore
Meaning
Self-test during the start sequence
The thermal imaging camera is switched on.
The battery charge is 51% to 100%.
The battery charge is 26% to 50%.
The battery charge is less than 25%, but is sufficient
for a further 5 minutes
Not paired
Pairing with another device is established
Overheating of the thermal imaging camera
Error in the thermal imaging camera
System fault
Meaning
The charging cradle is ready for operation.
The battery is fully charged.
Battery is 75% to 99% charged.
Battery is 50% to 74% charged.
Battery is 25% to 49% charged.
Charging process interrupted
Battery temperature outside permitted range
Battery can no longer be charged
|
Description