LEDs on the charging
cradle flash yellow (error
during charging process).
LEDs on the charging
cradle are off.
If the thermal imaging camera still does not function despite the specified
measures, it can be reset to the factory state. To do this, press the On/Off button
for at least 20 seconds. If the thermal imaging camera still does not function, it
should be sent back to Dräger.
6
Maintenance
6.1
Charging the rechargeable battery
Note the following points when charging the battery:
Charge the battery in ambient temperatures of 10°C to 45°C. The charger
stops charging and indicates an error to prevent damage to the battery when
temperatures are outside this range. The charger continues charging as
soon as the camera temperature reaches the permissible range again.
Dräger UCF FireCore
Cause
The battery can no lon-
ger be charged.
Battery temperature out-
side permitted range.
No power supplied to the
charging cradle.
Maintenance
Remedy
Replace the battery.
Leave the thermal imag-
ing camera in the
charging cradle and take
them to an area where
the temperature is
between 10°C and 45°C.
The battery will be
charged when its tem-
perature is correct.
It can take significantly
longer than an hour for
the temperature to equal-
ise and the charging pro-
cess to resume.
Check the functioning of
the power supply unit and
the connecting cable.
Clean the charging pins.
|
en