MONITOR INSTALLATION
F
ix the monitor connector to the wall.
Avoid to place the monitor near to heating sources, in dusty
locations or smoky environments.
To install the monitor directly over the wall, drill two holes of
Ø6mm. and use the supplied screws.
The upper part of the monitor connector must be placed
at 1,60m. height roughly. The minimum distance
between the monitor connector and the closest object
must be 5cm.
F
ix the monitor.
119
Place the monitor at right angles to the
connector and align the attaching holes of the
monitor with the attachment hooks of the
connector, as it is shown on the drawing.
Lock out the monitor. Press the right side till the
attachment clip locks the monitor firmly.
To disassemble the monitor from the connector,
use a plain screwdriver to release the
attachment clip. Remove the monitor from the
connector, with special attention do not falls.
120
MONITORS PROGRAMMING
P
rogramming the Platea/Tekna Plus monitors.
Set to ON the switch number 2 of the SW2 configuration dip switch, that's
accessible in the EL500SE module by opening the terminal connector
protection cover.
The door panel will reproduce a sound to advise that the system has
entered into programming mode.
In systems with more than one door panel, the programming process shall
be done on the master door panel only.
To program the monitor from a general door panel (if it exists), see page 112.
Switch off the monitor to be programmed.
Once the monitor is off, press the door release push button.
With the door release push button pressed switch on the
monitor.
To show that the system is ready for programming, the door
panel will reproduce a tone and the picture will appears
on the monitor. At this moment, the door release push
button can be released. Lift the handset to establish audio
communication with the door panel.
Each apartment must have one master unit only; in case of parallel units configure them as slaves,
both monitors or telephones.
Make a call to check that the monitor has been succesfully programmed.
Repeat these steps to program the rest of monitors.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the door panel will reproduce a tone to advise that the
system is still into programming mode.
Press the door panel push button that will
call to this monitor. At this moment the
door panel will reproduce a tone and the
monitor led will blink.
To program the monitor as master, switch it
off and on again.
To program it as slave, press the door
release push button.
To program it as slave with intercom
function press the
push button.