SYMPTOMS AND SOLUTIONS
The optoelectronic filter does not work.
Filter stays dark after the weld arc is extinguished or when no arc is
present.
Uncontrolled and sparkling switching: The filter lightens and darkens
when welding.
Side of the filter is lighter than the center of viewing area.
SAFETY LABEL
This label is displayed inside the welding helmet. It is important that the user understands the safety symbols signification. The list numbers match image numbers.
Legend :
A. Warning ! Beware ! There are possible dangers as per the different symbols.
1. Read the instructions carefully before using the product or before welding.
2. Do not remove the warning label and do not paint on it.
3. Follow settings instructions and maintenance of the filter, the protective screens, the headband and the hood.
4. Inspect the helmet and the UV/IR filter carefully. Replace damaged or worn parts immediately. Cracked, scratched, filter glasses and protective screens decrease protec-
tion. Replace them immediately to avoid damaging your eyes.
5. Warning, if the UV/IR filter does not tint whilst welding or cutting, stop immediately and consult the user manual.
6. Arc radiation can cause eyes and skin burns.
6.1. Use a welding helmet with a good filtration or opacity. Wear complete protective clothing..
6.2. The helmet, filter and protective screen do not gurantee unlimited protection against, shocks, impacts, explosions or corrosive liquid. Avoid welding or cutting in rough
environment.
6.3. Do not weld or cut above your head with this helmet.
7. Keep your head away from the smoke-filled area. Use a forced ventilation or a local aspiration system to eliminate smoke.
8. The oxyacetylene welding-cutting, laser or gas is not authorised with this helmet.
GYSMATIC TRUECOLOR 9.13
Activate the solar charge by exposing the cell to the light between 20 to 30 minutes - Check and
change battery if necessary.
Make sure that the potentiometer is set to the «welding» position (9 to 13)
Check and clean detectors if needed.
Adjust sensitivity knob to the lower position (level 1). If the welding place is extremely bright, it is
recommended to reduce light level.
Check arc sensors are not blocked from direct access to the arc light. Set the sensitivity level to 5.
It is a natural feature of LCD's, this symptom is not dangerous for the eyes. However for a
maximum comfort, try to keep an view angle at around 90°.