Installation
1
Preparing for installation
CAUTION: Always shut off the water supply before
removing an existing faucet or replacing any part of a
faucet. Open the faucet handle to relieve water pressure
and ensure that the water is completely shut off.
Shut off the water supply to the tub and
shower.
Verify that the hole sizes and positions of the
holes in the wall are correct :
The shower and tub spout outlet holes
should be 1-1/4 in. diameter.
For the cold water inlet (the right side)
and the hot water inlet (the left side),
cut or leave a 1-3/8 in. diameter hole
(recommended size is 1-3/4 in.). The
center to center distance between the
cold and hot water inlets is 8 in.
30 in.
48 in.
NOTE: Do not disassemble the cartridges during normal
installation. When reinstalling the cartridges, be sure to
insert the inverter with the text (a&b) on it upward as shown
in the diagram. This is necessary for proper operation of
the valve.
a
1-3/8 in. ~ 2 in.
1-3/8 in. ~ 2 in.
8 in.
b
2
Installing the supply
connections
NOTE: Hot water supply lines go into the "H" inlet; cold
water supply lines go into the "C" inlet.
Wrap thread sealant tape around the valve body
(D) threads in a direction the same to the thread
tighten direction, as shown.
Thread the waterline (1) to the valve body (D),
and tighten with a wrench.
Hot
3
Installing the shower outlet
connections
Wrap thread sealant tape around the valve body
(D) thread in a direction the same to the thread
tighten direction, as shown.
Connect the shower pipe (1) to the valve body (D).
Connect the pipe elbow (3) (not included) to the
end of pipe and tighten with a wrench.
7
Please contact 1-855-HD-GLACIER for further assistance.
D
1
1
Cold
3
Shower
1
D
HOMEDEPOT.COM/GLACIERBAY