FIRE-FIGHTING SAFETY MEASURES
When installing the appliance, the folloWing safety measures must be observed:
a) in order to ensure sufficient thermal insulation, respect the minimum safety distance from objects or furnishing components flammable
and sensitive to heat and from materials with flammable structure (see declaration of performance -
MINIMUM SAFETY dISTANcES ARE SHowN oN THE pRodUcT dATA plATE ANd lowER vAlUES MUST NoT bE USEd.
b) in front of the furnace door, in the radiation area, there must be no flammable or heat-sensitive objects or material at a distance of less than ...
Picture 7
- A.. . this distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is installed in front of the
whole component to protect;
c) if the product is installed on a no totally refractory floor, one must foresee a fireproof background. THE FlooRS
MAdE oF INFlAMMAblE MATERIAl, such as moquette, parquet or cork etc., MUST bE covEREd by a layer of no-inflammable
material (size according to regional law, see
the ash drawer must always be inserted when the appliance is in operation.
the solid combustion residues (ashes) must be collected in a metal container that is hermetically sealed and fire resistant. the appliance must
never be lit in the presence of gaseous emissions or vapours (for example: glue for linoleum, petrol, etc,). do not place flammable materials in
the vicinity of the appliance.
during the combustion, thermal air is emitted by involving the heating of areas, door and glass hearth, of
the door handles or controls, of the smokes pipe and, in case, of the front part of appliance.
AvoId To ToUcH THoSE pARTS wITHoUT A pRoTEcTIvE cloTHING oR wITHoUT AccESSoRY ToolS (gloves
resistant to heat, control devices). ENSURE cHIldREN ARE AwARE oF THESE dANGERS ANd kEEp THEM AwAY
FRoM THE FURNAcE wHEN IT IS oN.
wARN cHIldREN THAT THE dEvIcE bEcoMES vERY HoT ANd THAT IT MUST NoT bE ToUcHEd.
When using the Wrong fuel or one Which is too damp, due to deposits present in the flue, a flue fire is possible.
FIRST-AId MEASURES
should any fire arise in the stack or in the flue:
a)
close the feeding door.
b) close the registers of combustion air
c)
extinguish the fire using carbon dioxide fire-fighting means (co
d) seek immediate intervention of fire brigade.
do NoT EXTINGUISH FIRE USING wATER JETS. When the flue does not burn any more please arrange an
examination by a specialist in order to find possible cracks and permeable points.
bEAM pRoTEcTIoNS
considering the irradiation of the hearth, it is necessary to be particularly careful in protecting the beams While
designing your stack. consider the proximity of beams to the external surfaces of the hearth, on one side, and the
irradiation of the glass door, usually very close to the beams, on the other side.
in any case, it has to be considered that the internal or lower surfaces of this beam in flammable material must not come in contact with
temperatures higher than 65 °c.
wARNING: wE cANNoT bE MAdE lIAblE FoR A wRoNG opERATIoN oF THE plANT, wHEN IT doES NoT coMplY
wITH THE pRovISIoNS oF THESE INSTRUcTIoNS oR wHEN IT USES AddITIoNAl pRodUcTS NoT SUITAblE FoR THIS
dEvIcE.
24
24
Picture
1).
Picture 2
gives some examples of execution.
dust).
2
ENGLISH
Picture 7
- A..). All THE