Children should be supervised to
ensure that they do not play with
the tool.
Keep children away from the
battery charger and the working
area!
Keep your battery charger out of
reach of children!
Pull out the mains plug immediately
if the battery charger starts to
smoke or flames emerge!
Do not insert objects into the
ventilation slots on the battery
charger – there is a danger of
electric shocks and short circuits!
Do not use faulty battery packs.
In areas with high metal dust
exposure do not load any battery
packs with AIR COOLED chargers
(ASC 55 MULTI 8).
5. Overview
See page 2.
1 Battery pack (not in scope of delivery)
2 Sliding seat
3 Operation display
4 Warning display
5 Removable cord
6 Switch
6. Commissioning
Before plugging in, check to see that the
rated mains voltage and mains frequency, as
specified on the rating label, match your
power supply.
Devices such as this one, which generate direct
current, may have an effect on basic residual-
current circuit breakers. Use type F or better, with a
release current of max. 30 mA.
Before commissioning the charger, ensure that
the air slots are free. Minimum distance to other
objects is 5 cm.
6.1
Self-test
After inserting of mains supply plug the warning
display (4) and the operating indicator (3) will
shortly light up and the installed fan runs for a few
seconds.
8
6.2
Mounting to a wall
If the charger is to be mounted to a wall, it must be
suited to safely carry the weight of the charger
including battery pack (approx. 25 kg in total).
Use appropriate fixing material.
7. Use
7.1
Charging battery pack
Push the battery pack completely to the stop on
the sliding seat (2).
The operating indicator (3) flashes.
Note: To have the charge level displayed on Li-ion
battery packs, first take the battery pack out of the
charger and then press the button on the battery
pack.
7.2
Conservation charge
Once the charging process has finished, the battery
charger automatically switches to conservation
mode.
The battery pack can remain in the battery charger
and is therefore always ready for use.
The operating display (3) lights up continuously.
8. Fault
8.1
Warning display (4) lights up
continuously
Battery pack is not charged. Temperature too high/
too low. When the temperature of the battery pack
is between 0 °C and 50 °C, the charging process
begins automatically.
8.2
Warning display (4) flashes
• Battery pack is defective. Remove the battery
pack immediately from the charger.
• The battery pack was not pushed correctly onto
the sliding seat (2). See section 7.1.
9. Repairs
Repairs to the charger must only be carried out by
qualified electricians.
If the mains connection cable of this tool is
damaged, in order to prevent endangering
personnel and property it must be replaced by the

Publicidad