Installation, cleaning and replacement of
the separator (optional)
Figure 18
[ NOTE ]
Instructions describing how to fit the optional kits and the
relative operation and maintenance manuals are supplied
together with the optional kits.
[ NOTE ]
If there is only a dust deposit on the separator (4) allow the
dust to drop through the central hole.
The separator (4) should first be disassembled in order to be
perfectly cleaned:
■
Release the closing hooks (1) of the cover (2) and remove
the cover.
■
Remove the filter.
■
Unscrew the two screws (3) and remove it from the
container.
■
Replace the part if it is excessively worn.
■
Reinstall the separator (4).
■
Lock it and fix it by means of the two screws (3).
■
Fit the filter back in place, close the cover (2) and lock it by
means of the two the closing hooks (1).
Tightness inspection
Hoses check
Figure 19
Make sure that connecting hoses (1) are in a good condition
and correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
When sticky materials are treated, check for possible clogging
along the hose, in the inlet and on the baffle plate inside the
filtering chamber.
To clean, scrape the inlet from the outside to remove deposits.
Cover tightness check
Figure 20
If the gasket (1) under the cover (4) has become slack, remove
the screws (2) that lock the closing hooks (3) in place and allow
them to slide downwards until the cover closes perfectly.
Replace the gasket if the tightness is still not optimal.
Filtering chamber gasket check for machines
equipped with dust container
Figure 21
If the gasket (1) between the container and the filtering chamber
(3) fails to guarantee sealing:
■
Loosen the four screws (2) that lock the filtering chamber
(3) against the machine structure.
■
Allow the filtering chamber (3) to lower down and tighten
the screws (2) once it has reached the sealing position.
If an optimal seal is not yet obtained or if there are tears, cracks,
etc., the gasket must be replaced.
3707 - 3707/10 - 3907 - 3907/18 - 3907W
Filtering chamber gasket check for machines
equipped with Longopac® system
Ensure that the Longopac® bag is tight with the gasket (2).
Also check the seal of the gasket positioned on the discharge
clapet (1).
The gasket must be replaced if it is torn, cut, etc...
Disposal
The crossed-out wheeled bin symbol on the
equipment indicates that used electrical and
electronic equipment must be collected and
disposed of separately from household waste. The
correct disposal of the equipment will help prevent
potential
negative
environment and human health.
Electrical and electronic household equipment must be
disposed of at the separate collection points in the residence
area. Please note that commercial electrical and electronic
equipment should be disposed of separately from the municipal
waste stream. We will be pleased to inform you about suitable
disposal options.
Wiring diagrams
If the machine is equipped with a control panel, refer to the
paper wiring diagram provided with the machine documents.
17
Figure 22
consequences
for
[ NOTE ]
the
EN
GB
C65