OWNER'S MANUAL
15EC-CIA-SFS Sump Pump
This submersible pump is designed for use in basins or lift stations and
is suitable for pumping clean water with up to 1/2-inch (12.7 mm)
spherical semi-solids. Do not use the pump in applications where sew-
age or any other debris (gravel, sand, floating debris, etc.), abrasives,
or corrosives are present.
The pump motor is equipped with an automatic restart thermal protec-
tor and may restart unexpectedly. Activation of the thermal protector
indicates that the motor is overloaded or overheated. Refer to
bleshooting" on page
This product is covered by a Limited Warranty for a period of 3 years
from the date of original purchase by the consumer. For complete
warranty information, refer to www.LittleGiant.com.
Specifications
Model
HP Volts
15EC-CIA-SFS
1
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product's application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
• Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
• Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri-
cally disconnected.
• If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of
power.
• If the disconnect panel is not accessible, contact the electric company to stop service.
7.
Hz
Amps
115
60
8.1
"Trou-
Discharge
Intake
1-1/2" FNPT
1/2"
EN
ON Level
inches (mm)
inches (mm)
7 - 10 (178 - 254) 3 - 5 (76 - 127)
English
OFF Level