example, excess voltages to the load, but also provides higher resolution analogue control over
the specified ranges using the full 300º rotation of the controls.
To set new CUSTOM LIMITS turn the output off and select the 60V/10A range; preset limits are
shown in the display. Use the
set, precisely, the new custom limits required. Press and hold the CUSTOM LIMITS key; the
displays flash the new limits for ~2s, after which the lower (A) display shows
the new limits have been stored. Release the key; the displays now show the preset V and I limits
corresponding to the knob settings within the newly defined ranges.
If the new limits fall outside the power envelope (see Power Limit paragraph below), such that
operation could change from CV or CC (Constant Current) to UNREGulated (power limit) under
certain load conditions, the CUSTOM LIMITS lamp will flash during the setting process to indicate
this and will continue to do so until the range key is released. If the lamp is constantly on during
setting this indicates that V
CV or CC mode. CUSTOM LIMITS remains selected until another range key is pressed.
Reselecting CUSTOM LIMITS with a short key press recalls the same custom limits as last set.
When CUSTOM LIMITS is selected, the limit of the
above procedure when the
control itself can be usefully used to give an additional fine adjustment of ±1% (of the range
FINE
maximum).
Constant Voltage
The output voltage is adjusted using the
sets the maximum current that can be supplied.
The CV lamp lights to show constant voltage mode.
Constant Current
If the load resistance is low enough such that, at the output voltage set, a current greater than the
current limit setting would flow, the power supply will automatically move into constant current
operation. The current output is adjusted by the CURRENT control and the VOLTAGE controls set
the maximum voltage that can be generated.
The CC lamp lights to show constant current mode.
Instantaneous Current Output
The current limit control can be set to limit the continuous output current to levels down to 10mA.
However, in common with all precision bench power supplies, a capacitor is connected across the
output to maintain stability and good transient response. This capacitor charges to the output
voltage and short-circuiting of the output will produce a current pulse as the capacitor discharges
which is independent of the current limit setting.
Power Limit
The maximum current at different voltage settings is limited by the power envelope illustrated
below:
The power envelope is set to give 60V/3A, 35V/5A and 16V/10A under all supply conditions (both
outputs loaded); at lower output voltages the output power is restricted by the 10A current
maximum.
12
and
VOLTAGE controls and the CURRENT control to
MAIN
FINE
x I
<180W and that operation should therefore generally stay in
MAX
MAX
control is set at its mid-point, marked on the panel with a • . The
FINE
and
MAIN
XPF60-10D & DP
Power Envelope
VOLTAGE control is exactly as set by the
MAIN
VOLTAGE controls; the CURRENT control
FINE
SEt
to indicate that