Attach firmly the wall brace onto a wall through the
EN
four screw holes.
Lift the panel heater up to almost vertical position
and insert the two lower protruding parts of the
braces into the two lower openings of the back
cover of the panel heater. Then lift the panel heater
and insert the two upper protruding parts of the
wall braces into the two upper openings of the back
cover of the heater. Finally, put the two screws back
to their places and tighten them in order to install
the panel heater firmly to the wall.
BATHROOM OPERATION
The panel heater must be installed in accordance
with the normal trade practices and in compliance
with the national legislation (EU electricity directives
and regulations concerning special installations and
places of operation including bathrooms, shower
cabins HD60364-7-701(IEC 60364-7-701:2006)).
In case this panel heater is to be used in a bathroom
or other similar room, the following installation
requirements must be observed: the panel heater is
with IP24 protection (water drops protection). Hence
it can be installed in "Volume 2" (see the diagram
below) in order to avoid the risk of the control board
(power switch and thermo regulator) being reached
by a person who is in a shower or a bathtub. The
minimum distance between the appliance and a
water source should be not less than 1 meter and
it is compulsory the appliance to be wall-mounted!
If you do not feel sure about the installation of this
panel heater in a bathroom, we recommend you to
consult a professional electrician.
Note: If the above-mentioned instructions cannot be
implemented, it is recommended to install the appliance
in "VOLUME 3".
In wet premises the power source must be installed
at a height of at least 25 cm above the floor
(bathrooms and kitchens).
The installation must be equipped with a safety
fuse, and the distance between the fuse contacts in
disconnected condition should be at least 3 mm.
4
Operation and Storage Manual
OPERATION INSTRUCTIONS
Operation modes
Turn the panel heater on by pushing the switch in
position "I" (turned-on), then turn the regulator to
the desired level (1 to 6) as you take into account the
following relation between the power levels:
* – anti-freezing mode/ enabled when room
temperature falls below 5°C
1 / 2 – economy mode/ it maintains low room
temperature/ this mode is recommended to be used
at night and when there are no people present in the
room. This mode permits to maintain the set room
temperature while saving energy.
3 / 4 / 5 – comfort mode/ it maintains moderate room
temperature/ this mode is recommended to be used to
maintain relatively high comfortable room temperature
during the day.
6 – maximum power mode / it maintains HIGH room
temperature/ this mode is recommended to be used
when you need maximum high room temperature
Important: Thermo Regulator digits do not correspond
to certain room temperature levels, but they can be used
by users to memorize the relation between room temperature
and the thermo regulator settings.
When the room temperature is lower than the
temperature that you have set by the thermo regulator,
the panel heater starts its operation and will operate
until the room temperature reaches the set temperature
level of the unit. When the room temperature is higher
than the adjusted temperature of the appliance, the
panel heater will automatically go into "Stand by" mode.
PROTECTION
The appliance is equipped with a safety thermo turn-
off device, which automatically turns the heater off in
cases of extreme temperature of the panel heater /i.e.
overheating of the appliance/.
The safety thermo turn-off device will automatically
restore the heater operation when the temperature
of the appliance falls below the permissible ultimate
values.