2.2.3 Cleaning the filter Yee
!
WARNING:
Make sure the machine is turned off.
1
2
3
4
5
6
Important: Machine will not function with handles closed. It is recommended to clean the filter
weekly, depending on the use of the equipment. If you notice that the flow of the vat decreasing
it is necessary to clean the filter.
If the part is damaged, request EMERYMARK or the authorized dealer.
MODEL
EMP-200
EMP-500
EMP-1500
EMP-3000
56
1. Close the velves by turning down.
2. Place a container in case there is liquid spill.
3. Carefully open the filter cap with the included wrench, turn
counter clockwise.
4. Remove the sieve, wash it and return it to place. Check that the
sieve and o-ring are in good condition.
5. Check that the strainer and o-ring are in good condition. Do not
to force the part, ensure threads are aligned properly for proper
seal.
6. Re-open the valves by turning upwards.
MEASURE
COMPLETE
FILTER
FILTER CODE
1 1/4"
232025
1 1/4"
232025
1 1/2"
232024
2"
232026
SIEVE CODE
WRENCH CODE
232144
231040
232144
231040
232145
231041
232146
231042
www.emerymark.com