2. Parts Names
Outdoor unit
3. Operation
■
About the operation method, refer to the operation manual that comes with each remote controller.
3.1. Turning ON/OFF
[ON]
ON
OFF
Note:
Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about 3 minutes.
This is to prevent the internal components from being damaged.
■
Settable preset temperature range
Operation mode
Cool/Drying
Heat
Auto
Fan/Ventilation
3.2. Mode Selection
Fri
83
Room
Cool
Set temp.
Auto
83
Mode
Temp.
Fan
ON
RETURN SELECT
MENU
OFF
HOLD
en
What the blinking mode icon means
The mode icon will blink when other indoor units in the same refrigerant
system (connected to the same outdoor unit) are already operated in a
different mode. In this case, the rest of the unit in the same group can
only be operated in the same mode.
5
Service Panel
Press the [ON/OFF] button.
The ON/OFF lamp will light up in
green, and the operation will start.
When "LED lighting" is set to "No", the
ON/OFF lamp will not light up.
Preset temperature range
67 ~ 87 ºF (19 ~ 30 ºC)
63 ~ 83 ºF (17 ~ 28 ºC)
67 ~ 83 ºF (19 ~ 28 ºC)
Not settable
Each pressing of the [F1] button cycles
through the following operation modes.
Select the desired operation mode.
Cool
Drying
Auto
Heat
• Operation modes that are not available
to the connected outdoor unit models
will not appear on the display.
Power
Ref. Pipes
Indoor-Outdoor
Connection wire
Earth
[OFF]
ON
OFF
Automatic operation
■
According to a set temperature, cooling operation starts if the room
temperature is too hot and heating operation starts if the room
temperature is too cold.
■
During automatic operation, if the room temperature changes and
remains 2.0 °C, 4 °F or more above the set temperature for 15
Fan
minutes, the air conditioner switches to cool mode. In the same way,
if the room temperature remains 2.0 °C, 4 °F or more below the set
temperature for 15 minutes, the air conditioner switches to heat mode.
Cool mode
15 minutes (switches
from cooling to heating)
Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed
a few degrees warmer and heating operation is performed a few
degrees cooler than the set room temperature once the temperature is
reached (automatic energy-saving operation).
Press the [ON/OFF] button again.
The ON/OFF lamp will come off,
and the operation will stop.
15 minutes (switches
from heating to cooling)
Set temperature +2.0°C, +4 °F
Set temperature
Set temperature -2.0°C, -4 °F