The machine is equipped with a self-diagnosis system that can detect and report different kinds of
malfunctioning
Display
Er01
Rinse not allowed
Er03
Thermostop time out
Er04
Tank loading time-out
Er05
Tank probe "open"
Er06
Tank probe "closed"
Er07
Boiler probe "open"
Er08
Boiler probe "closed"
Motors circuit breaker
Er13
protection
Er14
Drive system failure
Er15
Drying probe "open"
Er16
Drying probe "closed"
Er17
Water inlet probe "open"
Er18
Water inlet probe "closed"
Er19
Pre-wash tank probe "open"
Er20
Pre-wash tank probe "closed"
Er25
Break tank load time out
Pre-wash tank loading time-
Er28
out
Er30
Boiler 2 probe "open"
Page 28 of 33
DISHWASHER INSTRUCTIONS MANUAL
Error description and possible solutions
Switch the machine off and back on again after having
checked that the overflow has been inserted correctly and
the water supply has been opened. If the problem
persists, contact the after-sales assistance centre
The boiler temperature has not reached the value set in
the pre-established time, contact the after-sales
assistance centre
The correct water level in the wash tank is not reached.
Switch the machine off and back on again after having
checked that the overflow has been inserted correctly and
the water supply has been opened.
If the problem persists, contact the after-sales assistance
centre
The probe that measures the temperature of the tank is
broken.
Heating is prevented. Contact the after-sales assistance
centre
The probe that measures the temperature of the boiler is
broken.
Heating is prevented. Contact the after-sales assistance
centre
Motors circuit breaker protection intervention, switch the
machine off and contact the after-sales assistance centre
Malfunctioning of the basket drive system; switch the
machine off and contact the after-sales assistance centre
The probe that measures the drying temperature is
broken. Heating is prevented. Contact the after-sales
assistance centre
The probe that measures the inlet water temperature is
broken. Contact the after-sales assistance centre
The probe that measures the pre-wash tank temperature
is broken.
Heating is prevented. Contact the after-sales assistance
centre
The correct water level in the break tank is not reached.
Switch the machine off and back on again after having
checked that the water supply has been opened and that
the water network flow rate is sufficient in compliance with
that stated on the data plate.
If the problem persists, contact the after-sales assistance
centre
The correct water level in the pre-wash tank is not
reached.
Switch the machine off and back on again after having
checked that the overflow has been inserted correctly and
the water supply has been opened.
If the problem persists, contact the after-sales assistance
centre
The probe that measures the temperature of boiler 2 is

Self-errors diagnosis