5.2 Mains connection

Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 220-240 V ~ 50 Hz. Make sure that the
socket-outlet is suffi ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up secu-
rely.
Check that the discharge line is fitted correct-
ly.
Make sure that the electrical connection is
220-240 V ~ 50 Hz.
Check that the electrical socket-outlet is in
good working order.
Make sure that no moisture or water can ever
reach the power connection.
Make sure that the equipment does not run
dry.
To switch off the equipment, pull the power
plug out of the socket outlet.
Note:
1. Lower the pump into the well or shaft by the
securing cable.
2. Ensure that the pump is at least 12 cm under
the surface of the water and approx. 30 cm
above the bottom.
3. Connect the mains plug to the socket.
The pump will start 3 seconds after the power
cable has been plugged in.

6.1 Automatic mode

The pump builds up pressure (e.g. the water tap
is closed) and then switches off automatically.
Thanks to the integrated non-return valve, the
pressure in the hose will be maintained until water
is removed again.
When the pressure drops below 2.5 bar, the
pump will switch on again automatically.
Anl_GE-PP_1100_N_A_SPK9.indb 18
Anl_GE-PP_1100_N_A_SPK9.indb 18
GB

6.2 Dry-running protection

The pump will be switched off automatically when
there is no longer any water for pumping.
Now the pump will check for water in cycles of 30
seconds ON / 5 seconds OFF (4x).
In other words, the test cycle will be repeated af-
ter 1 hr, 5 hrs, 24 hrs, 24 hrs ....
As soon as the pump is immersed again in water
to a depth of at least 12cm, it will be ready for
operation again.

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Unplug the power plug prior to any mainte-
nance work.
For mobile applications, the equipment
should be cleaned with clear water after every
usage.
In stationary use, it is recommended to check
every three months that the function is wor-
king properly.
Use a water jet to remove any lint or fibrous
particles that may have become trapped in
the housing.
Remove sludge from the shaft bottom and
clean the shaft walls every 3 months.
8.1 Cleaning the paddle wheel
If a lot of deposits collect in the housing, the bot-
tom part of the equipment must be dismantled as
follows:
1. Undo the 8 screws with a screwdriver (Fig.
2a).
2. The other cleaning steps are shown in Figs.
2b to 2e.
3. Clean the paddle wheel with clear water.
Important! Do not put down or rest the
equipment on the paddle wheel!
4. Assemble in reverse order.
- 18 -