PROTECTION
Overheating Protection
When the system enters into super high temperature protection status, the digital display shows "E03" and
continues to beep. After pressing STOP/CANCEL, the system comes back to normal standby mode.
Low Temperature Protection
When the system enters into super low temperature protection status, the digital display shows "E04" and
continues to beep. After pressing STOP/CANCEL, the system comes back to normal standby mode (except
microwave function).
Sensor Malfunction Protection
The system enters into protection mode when the system sensor is open circuited or short circuited. The
display shows "E05" or "E06" and buzzer will sound. After pressing STOP/CANCEL, the system comes back
to normal standby mode.
Button Adhesion Protection
In any state, if any button on the control panel is depressed for 60 seconds, the program stops working
immediately, the display will show "FAIL" and the system will sound a beep. If the button continues to be
depressed, beep will sound every one minute. During this time, no button will operate. After troubleshoot-
ing, press the STOP/CANCEL button to return standby mode.
HOW TO TEST FOR A MICROWAVE-SAFE DISH
To determine if a dish is microwave-safe, place the dish in the microwave along with a glass measuring cup
filled with one cup of water. Microwave for one minute on high and then carefully feel the dish. If it is warm,
it is not microwave-safe.