Flue assembly
• Slightly widen the two sides of the flue and hook
them behind the bracket 7.2 , making sure that they
are well seated.
• Insert the wooden profile 20 between the hood body
and the flue.
• Fix the lower section of the flue and the cable race-
way to the hood body from above, using the 6 screws
12m (2.9 x 18) provided.
Mounting the hood body
• Adjust the two screws Vr, on brackets 11a, to a
minimum.
• Hook the hood canopy onto the two brackets 11a.
• Remove the metal grease filters by turning the han-
dles provided.
• From inside the hood canopy, adjust the screws Vr to
set the Hood Canopy level.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120 mm, the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove possible charcoal filters.
EN
Connections
12m
20
ø 150
7.2
Vr
ø 120
9
9