2. Install the Valve - Ceiling Installations
NOTE: This section applies to ceiling installations only.
Remove the aspirator with a 3/8" hex wrench.
Turn the yoke over so that the supplies connect from the top of
yoke.
For bath and shower installations, reinstall the aspirator at the top
of yoke. Do not overtighten.
For bath only or shower only installations, discard the aspirator.
NOTE: Reversing the yoke will reverse the direction the lever
handles close. For proper lever handle operation, reverse the valve
units.
Before removing the valves, make sure they are in the open
position.
Torque the valves to 23-30 ft. lbs. (31-40.6 Newton/m) and turn to
the closed position.
Turn the hot valve counterclockwise and the cold valve clockwise.
Remove the thread protectors and reverse the valves.
Replace the thread protectors.
1031377-2-B
Ceiling
Supplies
Aspirator
Cold
Valve Unit
4