HT SOLAR03 Manual De Instrucciones página 31

Ocultar thumbs Ver también para SOLAR03:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
22/03/23 – 15:35
SETTINGS
MEMORY
PAIRING
HELP
INFO
STOP RECORDING
22/03/23 – 15:35
Inputs
Date & Time
Country & Language
22/03/23 – 15:35
Irr Front (F):
23050012
Irr Back (BH): 23050013
Irr Back (BL):
23050014
Input 4 1 x °C 
1. Press key MENU. The screen on the side appears on the display.
Use the arrow keys and press key ENTER to enter the internal
menus.
2. The following menus are available:
➢ SETTINGS  allows showing the probes' data, setting the
language and the system date/time.
➢ MEMORY  allows showing the list of saved recordings (REC),
see the residual space and deleting the memory's content
➢ PAIRING  allows pairing with the Master unit via Bluetooth
connection
➢ HELP  activates the help on line on the display and shows the
connection diagrams
➢ INFO  allows displaying the data of the remote unit: serial
number, internal version of FW and HW
➢ STOP RECORDING  (displayed only after a recording has
been started). It allows stopping a recording of the irradiance/
temperature parameters in progress on the remote unit,
previously started by a Master instrument paired with it (see §
5.4)
If a recording is stopped, the values of irradiance and
temperature will be missing for all measurements carried out by the
1.
Settings Menu
1. Use the arrow keys  or , select the menu "Inputs" as shown to
SET
the side and press ENTER. The following screen appears on the
display
2. Connect the reference cell HT305 to the input INP1 (monofacial
module) or the three reference cells to the inputs INP1, INP2 and
INP3 (Bifacial module). The instrument automatically detects the
serial number of the cells and shows it on the display as indicated
SET
in the screen to the side. In case detection fails, the serial number
is not valid or a cell is damaged, the message "Fault" appears on
the display.
3. In case of connection of the input INP4, the following options are
available:
➢ Off  no temperature probe connected
➢ 1 x ° C  t e m p e r a t u r e p r o b e P T 3 0 5 c o n n e c t i o n
(recommended)
➢ 2 x °C  coefficient for the connection of a double temperature
probe (currently not available)
➢ Tilt A  setting of the measurement of the modules' tilt angle
CAUTION
33
SOLAR03