ABYSS IP66 Installation Instructions
WARNING: To avoid possible electrical shock, be sure you have turned off the power at the main circuit panel.
Follow the steps below to connect the fan to your household wiring. Use the wire connecting nuts supplied
with your fan. Secure the connectors with electrical tape. Make sure there are no loose wire strands or
connections
..
Fig. 11
7. Intalled the metal safety cable into the house structure beams using the machine screws and flat
washer which provided, make sure that when the safety cable is fully extened the lead wires are longer
than the cable and no stress is placed on the lead wires.
7 | P a g e
ELECTRICAL WIRING DIAGRAM
1.
to receiver input wire (black, AC IN L) as shown in
(Fig. 11)
2. Connect the household neutral supply wire (white)
to the receiver input wire (white, AC IN N).
3. Connect the household ground wire to the fan
ground wires (green) from motor, downrod, fan
mounting bracket, and recevier ground wires
together. Connect all ground wires together using
the twist connector.
4. Connect the reveiver output wire (Pink, to motor
U) to motor input wire (Brown, To motor U).
5. Connect the reveiver output wire (Gray, to motor
V) to motor input wire (Yellow, To motor V).
6. Connect the reveiver output wire (Red, to motor
W) to motor input wire (Red, To motor W).
Connect the household live supply wire (black)
(Fig. 11 & Fig.12)