20
UK
INSTALLING THE ELECTRIC LOCK
If you need to install an electric lock, refer to figures (20) and (21)
1) ELECTRIC LOCK
2) ELECTRIC LOCK FASTENING PLATE
3) BUSHING
4) END-STOP FOR BUSHING
5) SPRING LATCH
6) THROUGH CYLINDER (ON REQUEST)
7) GATE
FINAL CHECKS
Power the system and run a complete opening and closing cycle checking that:
• The safety devices function properly;
• The gate moves smoothly;
• Good hold of the fastening brackets;
• That the power cable moves freely;
• The gate assembly conforms to EN 12453 and EN 12445;
• For further details and information on the reference standards, visit our site: www.gibidi.com
MAINTENANCE
Periodically check the gate structure, in particular:
- Check functioning of the hinges;
- Check that the leafs are correctly balanced. Excessive inclination of the leafs will result in faster wear of the
operator fastening brackets. Do the test by unlocking the operator and checking that the leafs do not move on their
own;
- Check good functioning of the safety devices;
- Unlock the operator and check that there are no points of friction along the entire travel;
- Check that there is no dirt or debris on the worm screw, and if so, clean and then lubricate the worm screw with
lubricating grease.
- Periodically check proper adjustment of the operator thrust force and the efficiency of the unlocking device for
manual operation (see the relative paragraph).
- The safety devices installed on the system must be checked every six months.
Gi.Bi.Di. Srl reserves the right to change the technical data without prior notice in relation to product development.
MALFUNCTIONING
For any unresolved malfunction, cut the power to the system and call in a qualified technician (installer). In the
period when the gate is out of service, activate the manual unlocking device to allow manual opening and
BL240