CONNECTING MAGICSTREAM
To wire multiple 12 Volt MagicStream
12 VAC MagicStream laminar and IntelliBrite Lights
IMPORTANT! When installing 12 VAC MagicStream laminar, connect the lights to the secondary 12
VAC output of the safety isolation (step down) transformer, then connect the IntelliBrite controller
to the 120 VAC primary input of the step down transformer.
Installing the IntelliBrite Controller in the Outlet box
The IntelliBrite Controller mounts onto a outlet box supplied with the unit. After wiring the IntelliBrite
Controller, check all wiring connections before mounting the controller into the outlet box.
To install the IntelliBrite Controller:
1. Neatly arrange the wires in the back of the outlet box.
2. Align the controller with the screw holes of the outlet box. Secure the controller to the outlet
box with the two (2) retaining screws.
3. Close the front door of the controller.
Retaining
PRINTED ON: 7/29/2009, 600054_ctlg pics.SLDASM
Screw
Retaining
Screw
INTELLIBRITE
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
TURN power OFF at circuit breaker -
Always disconnect power to the pool light at the circuit breaker before servicing
the light. Failure to do so could result in death or serious injury to installer, service
person, pool users, or others due to electrical shock.
Laminar to an IntelliBrite Controller:
®
Retaining
Screws
LAMINAR TO AN
®
CONTROLLER
®
Arrange
wires neatly
behind
Controller
Screw
hole
(X6)
16