PROBLEM
No coffee comes out.
The indicator light
D blinks RED.
The coffee is not hot
enough.
The lever cannot be
lowered.
The indicator light D is
lit up steady RED.
When a button is
pressed to dispense
coffee, the machine
seems to start but
then stops without
dispensing coffee, or
only dispenses a small
amount.
See the data plate
on the bottom of the
machine.
0.7 litres
ambient temperature:
10°C ÷ 40°C
330 mm
110 mm
22
English
Troubleshooting
POSSIBLE CAUSE
The water tank is empty.
- Cold cups / espresso
cups.
- Scale build-up in
machine.
- The used capsule drawer
is full.
- Capsule stuck inside the
machine.
Warming up problems.
Incorrect programming of
amounts.
Technical data
Approx. 3 kg
Max. 15 bar
< 70dB A
8 capsules
235 mm
Fill the tank with fresh water. Press
a button to refill the circuit. When
the buttons are lit up steady, the
appliance is ready to use.
- Prewarm the cup.
- Descale.
- Empty the used capsule drawer.
- Remove the stuck capsule.
Switch the machine off, then on
again. If the problem persists,
take the machine to an Authorised
Service Centre.
Reprogram the amount for the
button.
See the section "Programming the
amount of coffee in a cup".
The materials and
objects in contact with
food products comply
with the requirements
of European Regulation
1935/2004.
370 mm
CURE