FUMES DISCHARGE (only intended for personnel qualified to assemble the hood)
when the hood is not operating: refer to the instructions
When the kitchen hood is used simultaneously with other appliances that use gas or other fuels, the room must have sufficient ventilation, in accordance
with regulations in force.
The active carbon filters in this version are to be removed. Refer to the instructions
Deviation for Germany: when the kitchen hood is used at the same time as appliances that are powered by energy other than electricity, the negative pressure in the room must
not exceed 4 Pa (4 x 10-5 bar).
ASSEMBLY INSTRUCTIONS (only intended for personnel qualified to assemble the hood)
A
Phase
page 4
Place the support bar (S) on the installation wall at a height (H) from the cooker indicated in the figure (Fig. 1 ).
Use a spirit level to check the horizontal alignment and draw 2 marks at each end of the support bar, this is where the holes will be drilled (Fig. 2 - 3 ).
Drill the holes, insert 2 expansion plugs (ø 8mm) and fasten the bar with the relative screws (V1) (Fig. 4 ).
The fixing kit (screws, plugs, and brackets) supplied with the hood can only be used on masonry walls: should it be necessary to install the hood
onto walls in a different material, assess other fixing systems keeping the wall resistance and weight of the hood in mind (indicated on page 2).
B
Phase
page 4
Hook the hood onto the support bar (Fig. 1 ).
Adjust the alignment of the hood by using the fixing screws (Fig. 2 ). The upper screw (B) adjusts the distance from the wall, the lower one (C) adjusts vertical
scrolling.
To prevent the hood from falling due to a pressure below, fasten it to the wall with expansion plugs and relative screws (V2) using the appropriate holes on the
back of the hood (Fig. 3 ).
C
D
Phase
and
page 4
EXTERNAL EXHAUST HOOD VERSION (SUCTION)
Only for versions with an 800 m
Connect the air outlet connection of the hood to the external discharge with a suitable pipe.
HOOD VERSION WITH INTERNAL RECIRCULATION (FILTERING)
Check that the active carbon filters are assembled onto the hood, if not, install them as indicated in the instructions
If installed, remove the check valve assembled on the hood air outlet fitting (carry out the instructions described
EXTERNAL EXHAUST HOOD VERSION (SUCTION)
In this version, the kitchen fumes and vapours are conveyed outside through an exhaust pipe.
The air outlet fitting that extends from the upper part of the hood must be connected with the pipe that conducts the fumes and
vapours to an external output.
Do not connect the equipment to discharge pipes of fumes produced from combustion (for example boilers, fireplaces,
etc) and you are to comply with the regulations in force regarding external air discharge.
The fumes outlet pipe must have:
- a diameter not less than that of the hood fitting;
- a slight slope downwards (drop) in the horizontal sections to prevent any formation of condensation from flowing back to the
hood;
- the minimum required number of bends;
- minimum required length (long pipes with various bends can reduce suction performance of the hood and trigger vibrations
of the check valve).
If the fumes outlet pipe passes through cold environments such as attics, etc., it is possible that water condensation forms due to
sudden changes in temperature. In this case, you are required to insulate the pipes.
The hood supplied with an 800 m3/h motor is equipped with a check valve whose function is to prevent external air exchange
C
on page 4 for assembly.
HOOD VERSION WITH INTERNAL RECIRCULATION (FILTERING)
In this model, air passes through the active carbon filters to be purified and is then recycled into the kitchen environment.
Check that the active carbon filters are assembled onto the hood, if not, install them as indicated in the instructions
on page 6 .
If the hood is set up with a filtering version, the check valve must not be assembled: remove it if it is on the air outlet fitting of the
motor (carry out operations described in the instructions
3
/h motor: if you wish, install the check valve (M) as indicated in figure
H
on page 6 for removal.
C
on page 4 in reverse order).
C
.
C
17
I
on page 6.
on page 4 in reverse order).
H