Manual mode ProMax ClearDrain 11000, 14000
The pump is switched on when the sensor is inserted in the top-most position of the sensor
strip.
Metal contacts at the bottom of the sensor strip detect the minimum water level (deactivation
point). When the minimum water level is reached, the pump switches off with a brief delay.
Repeat the process: Reinsert the sensor in the top position of the sensor strip.
Setting the residual water level
The pump can pump the water down to a depth of 6 mm to 8 mm or down to 1 mm.
Residual water level 6 ... 8 mm: Fit the spacer ring and secure with the retaining ring (bayonet
closure).
Residual water level down to 1 mm (shallow extraction): Release the retaining ring (bayonet
closure) and remove the spacer ring.
Shallow extraction is only possible in manual mode.
EN
POX0006
POX0012
19