BFT Michelangelo BT A 60 Instrucciones De Uso Y De Instalacion página 45

Automatismos electromecanicos para barréras vehicular
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
qualified experienced personnel, in conformity with all the current standards
and with the use of appropriate materials.
Lay out the electrical installation with reference to the current electrical
standards.
Keep the mains supply connections clearly separated from the service con-
nections.
In the initial section of the electrical installation, fit a circuit breaker with a
contact opening distance equal to or greater than 3,5 mm, provided with mag-
netothermal protection and a differential switch having adequate capacity for
the appliance consumption. For the wiring, only use cables conforming to the
harmonised or national standards, having a cross section corresponding to the
initial protection, the appliance consumption and the installation conditions,
for example a 3x1.5 sq mm (H 05 VV-F) cable.
Terminal
JP13
JPC29
10
11
20
AUX 0 - 24V POWERED CONTACT
21
26
AUX 3 - FREE CONTACT (N.O.)
27
41
42
43
50
51
52
60
61
62
70
71
72
73
74
75
Y
#
Aux logic= 0 - 2ND RADIO CHANNEL output.
Contact stays closed for 1s when 2nd radio channel is activated.
Aux logic= 1 - SCA GATE OPEN LIGHToutput.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIGHT command output.
Contact stays on for 90 seconds after the last operation.
Aux logic= 3 - ZONE LIGHT command output.
Contact stays closed for the full duration of operation.
Aux logic= 4 - STAIR LIGHT output.
Contact stays closed for 1 second at start of operation.
Aux logic= 5 - GATE OPEN ALARM output.
The contact remains closed if the door stays open for longer than the "alarm time" parameter.
Aux logic= 6 - FLASHING LIGHT output.
Contact stays closed while leaves are operating.
INSTALLATION MANUAL
Definition
Board power supply:
TRANSF SEC
24V~ Transformer secondary winding
RECTIFIER BRIDGE
Rectifier bridge connection
MOT +
Connection motor 1
MOT -
AUX 0 configurable output - Default setting FLASHING LIGHT.
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
(N.O.) (MAX. 1A)
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND
MAINTENANCE. Refer to "AUX output configuration" table.
AUX 3 configurable output - Default setting 2ND RADIO CHANNEL Output.
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
(Max. 24V 1A)
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND
MAINTENANCE. Refer to "AUX output configuration" table.
+ REF RIF
Common references
RIFC
Reference closing RIFC (N.C.)
RIFO
Reference opening RIFO (N.C.)
24V-
Accessories power supply output.
24V+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
24 Vsafe+
Output active only during operating cycle.
Common
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 2 (N.O.) - Default TIMER.
IC 2
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Common
STOP, SAFE 1 and SAFE 2 inputs common
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
Configurable safety input 1 (N.C.) - Default PHOT.
SAFE 1
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the "Safety input configuration" table.
FAULT 1
Test input for safety devices connected to SAFE 1.
Configurable safety input 2 (N.C.) - Default BAR.
SAFE 2
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the "Safety input configuration" table.
FAULT 2
Test input for safety devices connected to SAFE 2.
Antenna input.
ANTENNA
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close
to the antenna can interfere with radio reception. If the transmitter's range is limited, move the antenna to a more
SHIELD
suitable position.
Proceed as explained below:
1. Remove the transformer cover.
2. Unscrew the screw which locks the cap (Fig. G Rif. 1) and take the cap out.
3. Fix the cables to the terminal bar (Fig. G Rif. 2)
L
PHASE
N
NEUTRAL
EARTH
4. To close the cap, reverse the actions in step 2.
5. Refit the transformer cover and secure in place by means of the slots located
on top of the transformer (Fig. G Rif. 3-4).
AUX output configuration
Description
MICHELANGELO BT A-
45

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Michelangelo bt a 80Michelangelo bt a 60

Tabla de contenido