Logic
Definition
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
Block pulses during
IBL OPEN
opening
Block pulses during
*IBL TCA
Block pulses during
IBL CLOSE
closing
OPEN IN OTHER
Open in other
direction
DIRECT.
Configuration of
safety input SAFE 1.
SAFE 1
Configuration of
safety input SAFE 2.
SAFE 2
Configuration of
command input IC 1.
IC 1
Configuration of
command input IC 2.
IC 2
48 -
MICHELANGELO BT A
INSTALLATION MANUAL
Cross out
Default
setting
used
1
 
0
 
0
 
1
 
0
 
TCA
0
 
0
 
0
72
6
74
2
61
 
3
62
Inputs configured as Start E, Start I, Ped operate
0
with 4-step logic.
Inputs configured as Start E, Start I, Ped operate
1
with 3-step logic. Pulse during closing reverses
movement.
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman
mode is enabled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
2
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
0
Pulse from inputs configured as Start E, Start I has effect during opening.
1
Pulse from inputs configured as Start E, Start I has no effect during opening.
0
Pulse from inputs configured as Start E, Start I has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I has effect during closing.
Pulse from inputs configured as Start E, Start I has no effect during closing.
1
0
Standard operating mode (left barrier).
1
Opens in other direction to standard operating mode (right barrier).
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
0
Input configured as Start E.
1
Input configured as Start I.
2
Input configured as Open.
3
Input configured as Close.
4
Input configured as Ped.
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
Optional extras
step-by-step mov.
3 STEP
CLOSED
OPENS
DURING
CLOSING
OPEN
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS