BFT Michelangelo BT A 60 Instrucciones De Uso Y De Instalacion página 43

Automatismos electromecanicos para barréras vehicular
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
x2
***
0---
10--
ALT
follow the user guide
add. start
hidden butt
Add. 2ch
hidden butt
erase 64
language
Control unit
software version
stat
vers
OK
bft . . .
+/-
No total
- +
manoeuvres(in hundreds)
0000
n. cycles
OK
+/-
- +
No radio control
devices memorised
n. remotes
OK
00
+/-
- +
List of last 30 errors
01.33
err
OK
02.01
........
30.15
+/-
0---
password
ACCESS MENUS Fig. 2
INSTALLATION MANUAL
150-
1520
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
See RADIO MENU
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
BAR safety edge input activated on slave motor
BAR 2
(opposite leaves connection)
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
Safety edge test on slave motor failed (opposite leaves con-
ER05
nection)
8k2 safety edge test failed
er06
Board hardware test error
ER1x*
Encoder error
ER2x**
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
Communication error with remote devices
ER5x*
Internal system supervision control error.
ER7x*
limit switch error
ErFx*
* X = 0,1,...,9,A,B,C,D,E,F
10--
150-
ok
Request with Protection Level logic set to 1, 2, 3, 4
DESCRIPTION
1520
prg
*** Password entry.
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or param-
eter/logic setting
Check photocell connection and/or param-
eter/logic setting
Check safety edge connection and/or param-
eter/logic settings
Check safety edge connection and/or param-
eter/logic settings
-
C h e c k
c o n n e c t i o n s
t o
m o t o r
- Hardware problems with board (contact
technical assistance)
Check the cable, the encoder card and the mo-
tor direction (if necessary) and reset the card
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected
accessory devices and/or expansion boards
Try switching the board off and back on again.
If the problem persists, contact the technical
assistance department.
check limit switch connections
MICHELANGELO BT A-
43

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Michelangelo bt a 80Michelangelo bt a 60

Tabla de contenido