GEAppliances.com
Terminal
Connections
Remote
Thermostat
- Class
2 (on some
models)
The controls (]re Ioc(]ted under (] pl(]stic cover
behind the front grille.
rl]
emove the front grille.See the Front Grille
section of C(]re (]nd Cle(]ning.
_]
Removethe screws securing the pl(]stic cover
over the wiring connections. Set (]side screws
(]nd pl(]stic cover.
-3] To m(]ke wiring connections, insert the wires
into the bottom of the termin(]ls (]nd tighten
screws securely.
After (]11 d esired connections h(]ve been m(]de,
repl(]ce the pl(]stic cover (]nd front grille.
The owner is responsible for m(]king (]11
connections (]nd setting the (]ppropri(]te dip
switches.
When connected, the unit will be controlled
by (] remote thermost(]t.
NOTE:The number 3 dip switch must be in
the en(]bled (UPJ position to (]ctiv(]te the remote
thermost(]t. (Seethe inst(]ll(]tion instructions
supplied with the remote thermost(]t.)
Terminal
onnectlons
location
nderfront
grille
........................
__...........
_
IMPORTANT:
The thermost(]t connections provide 24 VAConly.
If using (] digit(]l/electronic w(]ll thermost(]t,
ensure it is comp(]tible with 24 VACsign(]l. See
the Inst(]ll(]tion Instructions for the w(]ll thermost(]t.
NOTICE:
D(]m(]ge to (] w(]ll thermost(]t or to the electronics
c(]n result from improper connections. Special
c(]re must be used in connecting the wires. No line
volt(]ge connections should be m(]de to (]ny circuit.
Isol(]te(]11 w ires in building from line volt(]ge.
Red- 24 V AC only
Green- Low SpeedFan
Green- High Speed Fan
Yellow- Compressor
White - Heater
Common - Ground
9