Installation
Instructions
ELECTRICAL REQUIREMENTS
Read
these instructions
completely
and carefully.
A WARNIN o
RI:DUCE
Tin:
RISK OF I_]RI:, ELECTRICAL
SHOCK
AND
PERSONAL
INJURY:
DO NOT USE AN EXT_SION
CORD
ORAN
ADAFFER
PLUG WITH THIS APPLIANCE.
Washer must be electrically
grounded
in accordance
with local codes and ordJnmlces,
or in the absence
of local codes, in accordance
with the NATIONAL
ELECTRICAL
CODE, ANSI/NFPA
NO. 70.
CIRCUIT
- ]ndixidual,
properly
polarized
and grounded
15-amp branch
circuit
fllsed with 15-amp time-delay
fllse
or circuit breaker:
POWER
SUPPLY - 2-Mre, with gromM,
120-xolt, single-
phase,
60-Hz, Mternating
CmTent.
OUTLET
RI:CEPTACLE
-
Properly
grounded
3-prong
receptacle
to be located
so the power supply cord is
accessible
when
the washer is
in an installed
position.
GROUNDING
REQUIREMENTS
kWARNING:
hnproper
connection
of the
equipment
grounding
conductor
can result
in a risk
oI electrical
shock.
Check
with a licensed
electrician
if you are
in (loubt
as to whether
tile appliance
is
propedy
grounded.
1,
Tile
washer
MUST
be grounded.
In tile event
ot
malfimction
or breakdown,
grounding
will reduce
tile risk of electrical
shock
by providing
a path
of least
resistm_ce
fi)r electrical
ctm'ent.
,
Since your washer is equipped
Mth a power supply
cord having an equipment-grounding
conductor
and
a grounding
plug, tile plug MUST be plugged
into an
appropriate,
copper-wired
receptacle
that is properly
installed
and grounded
in accordance
with all local
codes and ordinances
or in tile absence
of local codes,
with the National
Electrical
Codes, ANSI/NFPA
70
(lamst edition)./I
in doubt,
call a licensed
electridan.
DO NOT
cut off or alter tile grounding
prong on tile
power supply cord. In situations
where
a two-slot
receptacle
is present,
it is the owner's
resp(msibili F t()
have a licensed
electrician
replace
it with a properly
grounded
three-prong
grounding-t)pe
receptacle.
WATER SUPPLY REQUIREMENTS
Hot and cold water tilucets MUST be installed
within
42 inches
(107 cm) of your washer's
water inlet. Tile
tilucets MUST be 3/4"
(1.9 cm) garden
hose-type
so
inlet hoses can be connected.
_,Vater pressure
MUST
be
between
10 and 120 pounds
per square
inch. Y()ur water
department
can advise you of your water pressure.
Tile hot water temperature
should
be set to deliver
water at 120 ° to 140 °F (48°-60°C).
DRAIN REQUIREMENTS
1. Drain capable
ot eliminating
17 gals (64.3 I.)
per minute.
2. A standpipe
diameter
of 1 1/4'
(3.18 cm) minimum.
3. Tile stmMpipe
height above tile floor
should
be:
Minimum
height:
24" (61 cm)
Maximum
height:
96" (244 cm)
BACK
r_,,,, l
96 in.
I
(244 cm)
I
i
Max.
I
I
I
I
NOTE:
Tile
drain
hose
attached
to tile washer
can reach
a 58"
(147 cm)
high
stmMpipe,
For a higher
stmMpipe,
contact
an authorized
parts
distributor:
17