Pump Reassembly - Flotec FP5200 Serie Manual Del Usuario

Bombas centrífugas auto cebadoras
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance
Figure 24 – Hold Shaft
3027 0997
Figure 25 – Assemble Pump
For parts or assistance, call Flotec Customer Service at
Step 10. Hold motor shaft with 7/16" open end wrench on shaft flats
Step 11. Replace impeller screw (if used) by turning counterclockwise
To avoid electrical
shock hazard, use
Step 12. Remount diffuser on seal plate with two screws.
insulated-handle
screwdriver to
Step 13. Follow instructions under "Pump Reassembly".
short capacitor ter-
minals as shown.

PUMP REASSEMBLY

Step 1. Clean gasket surfaces on pump body and seal plate; install new
Step 2. Slide motor/seal plate assembly into pump body. Secure with
Step 3. Replace base mounting bolts.
Step 4. Replace motor wiring; replace drain plug.
Step 5. Prime pump according to instructions. See "Operation."
Step 6. Check for leaks.
(Figure 24) and screw impeller onto shaft. Be sure you do not
touch capacitor terminals with body or any metal object.
Tightening impeller will automatically locate seal in correct
position.
(left-hand thread) into end of shaft.
gasket.
capscrews (Figure 25).
1-800-365-6832