OPERATION
Controls
The hood is operated using the (5) push-but-
tons located on the right side of the hood.
The light switch turns the halogen lights on
and off. Push the light switch once to turn the
lights ON - push a second time to turn the
lights ON to a brighter level - push a third time
to turn the lights OFR
The blower on-off/speed
I switch turns the
blower on to its lowest running speed. To turn
OFF the blower, push in and hold this blower
switch for approximately
2 seconds.
j
BLOVVER
_
SPEED
4
J_BLOWER
_
SPEED
3
_BLOWER
_
SPEED 2
_BLOWER
O_
ON-OFF/
SPEED 1
__
LIGHT
SWITCH
The blower speed 2 switch turns the blower on to medium-low running speed.
Pressing this switch a second time sets a timer which keeps the blower operating
at this speed for 10 minutes. The LED will blink during this time and the blower will
shut off automatically.
The blower speed 3 and blower speed 4 switches operate the same as blower
speed 2 switch except: Blower speed 3 is medium-high
and blower speed 4 is
high.
After every 30 hours of operation, the LED above the "blower speed 1 switch" wilt
be illuminated (RED) and blink for 30 seconds after turning off the blower. This is a
reminder to clean the grease filters. Once the grease filters are cleaned and installed,
press in and hold the "light switch" button for approximately
2 seconds during the
blink of the LED.
HALOGEN
BULBS
This range hood requires two halogen bulbs
(Type MR16, 12V, 20W).
ALWAYS SWITCH OFF THE ELECTRICITY
SUPPLY BEFORE
CARRYING
OUT ANY
OPERATIONS ON THE APPLIANCE.
To change bulbs:
1. Loosen
the
ring
nut
by
turning
it
counterclockwise.
2. Pull the bulb downwards to remove - DO
NOT ROTATE. CAUTION:
BULB MAY BE
HOT!
3. Replace with Type MR16, 12 volt, 20 watt
halogen
bulb.
RING
-9-