Descargar Imprimir esta página

Taurus ALPATEC AC2600 RVKT Manual Del Usuario página 21

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
This symbol means that if you want to
dispose of the product, after the end of its
life, you must deposit it by the appropri-
ate means at the disposal of an autho-
rized waste manager for the selective
collection of Waste Electrical and
Electronic Equipment (WEEE).
Model AC2600RVKT/ AC2600KT
Rated capacity for cooling (P
Rated capacity for heating (P
Rated power input for cooling (P
Rated power input for heating (P
Rated Energy efficiency ratio (EER
Rated Coefficient of performance (COPd)
Power Consumption in Standby mode (P
Electricity consumption of single/double duct appliances (Q
Sound Pressure level (L
Global warming Potential (GWP)
(*) Only available in AC2600RVKT model
INSTRUCTIONS FOR REPAIR-
ING APPLIANCES CONTAIN-
ING R290
GENERAL INSTRUCTIONS
CHECKS TO THE AREA
- Prior to beginning work on systems containing
flammable refrigerants, safety checks are nec-
essary to ensure that the risk of ignition is mi-
nimised. For repair to the refrigerating system,
the following precautions shall be complied with
prior to con-ducting work on the system.
WORK PROCEDURE
- Work shall be undertaken under a controlled
procedure so as to minimise the risk of a flam-
mable gas or vapour being present while the
work is being performed.
GENERAL WORK AREA
- All maintenance staff and others working in
the local area shall be instructed on the nature
of work being carried out. Work in confined
spaces shall be avoided. The area around the
workspace shall be sectioned off. Ensure that
for cooling)
rated
for heating)*
rated
)
EER
)*
COP
)
d
)
SB
)
WA
This symbol means that the product may
have batteries or batteries inside it,
which must be removed before
disposing of the product. Remember that
batteries must be disposed of in special autho-
rized containers. And they should never be
thrown into the fire.
, Q
)
DD
SD
the conditions within the area have been made
safe by control of flammable material.
CHECKING FOR PRESENCE OF REFRIGERANT
- The area shall be checked with an appropriate
refrigerant detector prior to and during work,
to ensure the technician is aware of potentially
flammable atmospheres. Ensure that the leak
tection equipment being used is suitable for use
with flammable refrigerants, i.e. nonsparking,
adequately sealed or intrinsically safe.
PRESENCE OF FIRE EXTINGUISHER
- If any hot work is to be conducted on the
refrigeration equipment or any associated parts,
propriate fire extinguishing equipment shall be
available to hand. Have a dry powder or CO 2
fire extinguisher adjacent to the charging area.
NO IGNITION SOURCES
- No person carrying out work in relation to a
refrigeration system which involves exposing
any pipe work that contains or has contained
flammable refrigerant shall use any sources
of ignition in such a manner that it may lead to
the risk of fire or explosion. All possible ignition
2,645 kW
2,4 kW
1,017 kW
1,043 kW
2,60
2,30
0,5 W
Cooling:
Q
: 1,017 kWh/h
SD
Heating: *
Q
: 1,043 kWh/h
SD
65 dB(A)
3 kgCO
eq.
2

Publicidad

loading

Este manual también es adecuado para:

Alpatec ac2600 kt