4.3.2 Temp mode with two probes
• If the main display shows "t", press MODE to select TEMP MODE. The
main display shows °C or °F in TEMP MODE.
• If a second temperature probe is used in TEMPERATURE MODE, the de-
vice automatically switches to Delta-T mode.
• In Delta-T mode, a temperature difference between the inner and outer
ring of 30°C (54° Fahrenheit) is set as standard.
• Press START/STOP to turn the heater on. The main display will show the
current temperature of the workpiece on the bearing inner ring.
• As soon as the maximum temperature difference is reached, the display
shows the temperature on the inner and outer ring alternately. The higher
temperature always shows the temperature on the bearing inner ring.
• As soon as the selected temperature has been reached, the heater demag-
netises the workpiece and generates an acoustic signal for 10 seconds or
until the START/STOP button is pressed.
• If the workpiece remains on the heater, it switches on again as soon as
the temperature of the workpiece falls 10°C below the setpoint. Press
START/STOP to switch off the heater and demagnetise the workpiece.
• Press the START/STOP button to stop the heating process.
• Remove the workpiece with suitable handling equipment.
• The IH 045 unit is now ready to heat another part with the same settings.