Figure 4 - Top of Generator
1 AMP
Control Fuses
Aroma Power
connection 15
AMP 120V
Aroma
Power Light
Figure 5 - Sensor Installation - Inside Steamroom
NOTE: Location of the sensor is as follows:
a) Single tier seating - 6 feet above floor.
b) Double tier seating - 7 feet above floor.
c) Place sensor on a wall adjacent or opposite of steam head. Do NOT place
sensor above the steam head.
5/8" Hole
No. 8 Plastic
anchors
No. 8 Screws
1" Long
50' sensor cable
Heater
Contactor(s)
H N G
GND
L1
L2
L3
Aroma
Fuse
Power
(See Page 19, Specification Chart)
Cable to
Steam Generator
1
Temperature
4
Sensor and Housing
(Shipped Assembled)
Optional Steam
Solenoid #2
Water
Level
Probes
XLow
High
Pressure
Control
STEPS TO INSTALL SENSOR:
1) Take new sensor assembly and connect to 50'
sensor cable. Please observe polarity of the 50' cable.
Make sure the male end of the cable is routed toward
the sensor in the steam room.
2) Peel off adhesive backing from sensor.
3) Carefully apply silicone sealant around rear edge.
4) Feed wires back into wall and press sensor firmly to
wall (be careful to align plate holes with anchor holes).
5
5) Install screws, and snap chrome cover back into
place.
6) Temperature sensor assembly must form a 100%
water tight seal to the wall using silicone supplied.
3
Male end
2
10
Steam
Solenoid #1
Loosen union to rotate
solenoids to the optimal
installation position
Reset
Button
Limit
Control
50 Foot Sensor Cable
Safety Relief
Valve
Male end
114415 Rev. F