Descargar Imprimir esta página

Amana AKS3040 Manual De Instalación página 7

Ocultar thumbs Ver también para AKS3040:

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical Wiring Information
This appliance is equipped with a grounded type power
cord. A grounded outlet must be provided. It is
recommended, for convenience, the outlet be located
(with reference to figure 6) as in A or B, below:
A. If no other appliance is to be installed below this
appliance: within either the shaded area or the cross
hatched area shown in figure 6.
B. If a Model AOES3030 or AOCS3040 Series Electric
Wall Oven is to be installed below this appliance,
either:
1. within the cross hatched area of figure 6, or,
2. within an adjacent cabinet.
If a wall oven is to be installed below this appliance and
the counter units outlet is to be mounted within the cross
hatched area of figure 6:
1. The cabinet's lower front panel, below the oven, must
be made removable for access to the outlet.
2. A clearance hole for the power cord's plug (1-1/4" (3.18
cm) dia is recommended)
must be provided through the
oven's floor support shelf and, if necessary, through the
slats supporting the shelf. The clearance hole should
be located as near as practical to the rear of the shelf.
If the outlet is to be mounted in either a left or right
adjacent cabinet, a clearance hole, as described above,
must be provided in the dividing wall between the
cabinets. Figure 4; page 5, illustrates a typical (left side)
dividing wall. The clearance hole (not shown in figure 4)
can be located as is convenient in this left wall or in the
corresponding right wall.
In planning any installation, note that the free length of
this appliance's power cord, extending beyond a point
3-3/4" (9.53 cm) left of the nominal center of the rear wall
of the burner box, when viewed from the front of the unit,
is approximately 46" (117 cm).
User may experience occasional circuit tripping if Ground
Fault Circuit Interrupter (GFCl) outlet or breaker is in use.
WARNING
Electrical Grounding
Instructions
This appliance
is equipped
with a (three-prong)
grounding
plug for your protection
against
shock
hazard
and
should
be plugged
directly
into
a
properly
grounded
receptacle.
Do
not
cut
or
remove
the grounding
prong from this plug.
WARNING
THIS
APPLIANCE
MUST
BE
DISCON-
NECTED
FROM ITS ELECTRICAL
SUPPLY
AT
THE
WALL
RECEPTACLE
BEFORE
SERVICING
THE APPLIANCE.
3 1/2" (8.89 cm)WIDE
SLATS
WHEN
A WALL
OVEN
IS INSTALLED
BELOW
30" MODEL
__-_,._---W_---_,
iiii_ii_!_!iiiiiiiii_ii_iiiiiiiiiiiiiii_i_iiii_iiiiii_i_ii_iiiii_ii_i_!!_!_!_!_i_!iiiiiiiii
_iiiiiiiii_iiiiiiiiii_iiiiiiii_iiiiiiiiiiiiiiiiiii_iiiii!ii!_iiiiiiiiiiii!ii_iiiiiiiiiiiii!!ii!!!!!!!!!
i_iiiiiiiii_iiiiii_iiiiiiii_ii_i_i_iiiiiiiiii_iiii_iiiiiiiii_iii_ii_iiiiii_i_i_ii_i_iiiiii_i_.
iii_ii_iiiiiiiiiiiiiiiiiii!iiiiii!_iiiiiiiiiiii!_!!!i!!ii_i_iiiiii:i!_
_iiiiiiiiiiiiiii!ii!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!i!!!!!_!!_!!i!!!i!!!!i!_i!!!_ii!i!!iii!iiiiiiiiiiiii
ii!i_i!_i!_;_;;_!!_i!!!!_!_ii_i_!_i_i!iiiiiii_iiiiiiiiiiiiiiiii
_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_iiiii_iii_i_iiiiiiiiiiiiiiiiiii_
i!!!!!_i_iiiiiiiiiiiiiiiiiiiiiiii!!i!!iiii!ii!!!!_!!!!i!!_i!i!!!!!!!!!!!!_!_!_ii_iii_iiiiii_iiii
_!!!!!!_iiiiiiiiiii_i_iii_iii_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_ii_iii_iiiii_i_!!!!!!!i
_!!!!!!!!!i_!iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_i_ii_!_!!!!!!_!!!!!!!!_i
L_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii!!!i_i_
CABINET BOTTOM
3 13/16"
9.7 cm
I
l
i
1
i
29 3/8"
74.61
cm
37 3/16"
94.46
cm
i
4" MAX.
10.16 cm
FIGURE 6

Publicidad

loading

Este manual también es adecuado para:

Aks3640